AboutUs arrow Productions
Sunday, 05 September 2010
 
 
Fill Packings Print E-mail

 Film Fill Packings Of Paydar Industry Co are, made of best poly vinyl chloride (P.V.C) sheets , that with added special articles in ASTM Standard  tests Stabilize , Impact resistance , Tensile Strength , Heat resistance , Conformed with CTI Bulletin  STD- 136 ;and also , U V Stabilizer and Bio Stabilizer , such as Legionella bacterium that is present in almost all natural water sources .In addition  in the Industrial cooling Tower that requires a sources of nutrient form the water such as algae or dead bacteria in sludge or Slime ; enable to thrive. Legionella bacterium must be carried in sufficient concentration in aerosols not larger than 5 microns in size, and these aerosols must be in haled and then Penetrate deep into the lungs in order to set up an infection.

The another benefit is corrugation sheet , and wave is the type most appropriate for cooling tower application where the water is relatively clean and tower volume must be minimized .
Packing are in various designs with cross- Flute and Vertical flute in Honey comb tips, accurate for cross Flow or Counter Flow, with different relations of surface to volume and thickness.

To see Complete Information  Clik  Read More 

 

Read more...
Drift Eliminator Print E-mail

  

The use of P.V.C Drift Eliminators, become popular from 1970 till 1980, due to reduced cost and higher efficiency for drift removal. Earlier P.V.C Drift Eliminators, designed with drift rates of < 0/01 Percent.

Rresearch and an emphasis on environmental emissions continued to drive the evolution of Drift Eliminator designs some of which can now provide drift rates from 0/005 percent to as low as 0/0005 percent.

 The Specifications of the Drift Eliminators are similar to the Fill Film Packings and they are in PE -130, PE – 260 Models.

TECHNICAL SPECIFICATIONS OF DRIFT ELIMINATORS: 

Using model of the PE-130 DRIFT ELIMINATORS and to set the packs beside each other to install on the vast surfaces, they provide easy movement, installation,controlling and service as well.

When the mixture of air along with drops of water with velocity of 2.5-3.5 m/sec(500-700 FPM) move through their nets, they are able to separate 99% of water drops bigger than 65 mic from the air.

The drift modules are fabricated from rigid corrugated PVC sheets that are conductive to cooling tower and UV protector. The drift modules are  resistant to rot, fungi, bacteria and inorganic/organic acid and alkalis commonly found in cooling towers.

The above models are made of upvc with 5 years guarantee.

To see Complete Information  Clik  Read More 

 

Read more...
Statistics
Members: 2
News: 47
WebLinks: 7
Visitors: 13376
 
Top! @2006-2007 Paydar Industry Co. Top!